EVOLT AC | LIGHT & CHARGE

Compact, robust and compliant with calibration law

EVOLT AC | LIGHT & CHARGE Compact, robust and compliant with calibration law

AC charging stations for public spaces

SWARCO’s eVolt Light & Charge series combine slim and innovative design with an outstanding technology. Thereby they are suitable for charging in public and semi-public areas and an optimally coordinated and functional charging system for the highest demands. Numerous options ensure that the basic device can be adapted completely to the customer’s needs. The device can be mounted on walls, posts or in slender single or double units on parking spaces. Especially convincing: the interaction with SWARCO backend solutions for loading and parking.
CONFORMITY WITH GERMAN CALIBRATION LAW

The charging station which is certified by the German Physical Technical Federal Institute (Physikalisch Technische Bundesanstalt, PTB) records the charging transactions and stores a digital signature in the device.
Thus the user has the possibility to compare the data with his payroll.


USABILITY
  • Modules that are easy to install and combine 
  • Wall mounting (mounting without foundation possible)
  • One-hand operation
  • Connection to backend: Fast overview of the loading processes, billing, customer tariffs via SWARCO backend & app


MODULAR

The basic unit can be supplied in different enclosure variants depending on your location. The device avoids unnecessary displays, at the same time the state of charge is indicated via LED and smartphone app.

INTELLIGENT TECHNOLOGY

Modern charging stations communicate intelligently with vehicles and IT backend systems. The eVolt Light & Charge charging stations are right up to date here. This makes them ideal for loading in public and semi-public parking spaces, in fleets or in parking garages. Two stations can share one modem.

IMPORTANT PERFORMANCE FEATURES
  • Enclosure: aluminium frame: light, robust, elegant, anodized; polyurethane cover with clear meter window for eHZ meters
  • Vandalism protection: locked charging sockets, no displays
  • Lighting: charging socket and RFID Reader
  • Certified in accordance with calibration law
  • Full safety engineering
  • Load management via OCPP
  • ISO/IEC 15118 vehicle communication

Technical Details

General InformationLight & Charge Serie
Charging modeMode 3 charging points
Number of charging points1-2
DesignAnodised aluminium, white aluminum, polyurethane, graphite
Enclosure dimensions (WxHxD)300x1475x500 mm max. (double stele with 2 basic units) | 144x1475x180 mm (sinlge stele)
ClosureMachine cabinet key or optional cylinder lock
Weightapprox. 60 kg(double stele) | approx. 30 kg (single stele)
Charging pointType 2 socket with shutter and one-hand operation, automatic locking of the charging plug at the start of the charging process as well as unlocking at the end and in case of power failure
Options
  • Various enclosure variants (wall/floor mounting)
  • Floor shaft for embedding in concrete, DEHNGuard© surge protection
  • Attached charging cable (4m)
  • Individual branding (logo, advertising), RFID cards, if desired with your own logo
  • Extensive billing possibilities via the SWARCO backend (e.g. for home charging of company vehicles orprivate employee vehicles in the company


Communication & status display
ModemGSM Modem, 2.5G Edge, 3G UMTS and 4G LTE
Communication protocolOCPP 1.6
Authentication optionRFID card reader (13.56 MHz), mobile phone, QR code, reservation function is supported
Status displayRGD LED ring with sliding cover, via APP


Electrical data
Rated voltage, rated frequency230V AC / 400V AC, 50/60 Hz
Maximum input current32A 3~ / 2x32A 3~ (depending on charging capacity)
Network systemTN / TT
Connection terminals3- or 5-pole connection (16mm²) incl. PE terminal FI 
Integrated fuses
  • FI circuit breaker type A, 40/0, 03A
  • DC residual electricity detection via measuring electricity tranformer
  • LS switch C32A for short-circuit / overload protection
Output power (per charging point)3.7 kW/ 11kW / 22 kW (configurable)
Meter (per charging point)2 x eHZ EDL 21/40 compliant smart meters (incl. viewing window)


Working conditions
IP Degree of protection / Impact strenghtIP 54 / IK 10


Standards / Guidelines
Operating temperature-25°C to +40°C
StandardsDIN EN 62196-2, IEC 60364-7-722:2015, ISO/IEC 15118